-40%
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP 4 Ton 2 Z
$ 2164.27
- Description
- Size Guide
Description
Powered byFrooition
bizlanderhvacsolar
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP 4 Ton 2 Z
Item Description
YMGI 48000 BTU
4 Ton
TWO ZONE
WALL MOUNT
24000 BTU + 24000 BTU
Designed for Office, Shop,
RESTAURANT
DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
208-230V 21 SEER DC INVERTER
MITSUBISHI
COMPRESSOR
IF YOU REQUIRE DIFFERENT INDOOR MATCH
PLEASE CLICK HERE AND CONTACT US
Model
:
WMMS-48CH-V2B(59)4/24EW-24EW
Condition
: Brand New item unused unopened in original sealed package
This System is idea for Commercial space with high traffic area such as Office with open space, garage workshop, restaurant and cafe with kitchen area, shops and Bars etc
Function
Cooling
Heating
Dehumidification
Air Purification
Description
Dual Zone Air Conditioner with Heat Pump
One Outdoor unit with 2 Indoor units (24000 BTU, 24000 BTU)
4 Tons Heating Cooling And Dehumidification
21 SEER DC Inverter Compressor from Mitsubishi
Super Quite Auto Restart, digital Timer and Turbo Mode
Feature
Variable Speed Compressor: Mitsubishi
21 SEER efficiency, DC inverter technology
AHRI certified
Whisper-quiet operation, Low voltage start
Stable Operation at Low Frequency
Random pitch cross flow fan wheel
Dry anti-mould coil
LCD display, Turbo mode, 3 fan speeds
Quick access, washable air filter
Auto level swing, Wide angle air distribution, Auto Restart,
24-hour programmable timer, Sleep mode, Independent Dehumidification
Enhanced copper/coil, Corrosion resistant cabinet, Thoroughly tested ensure longer performance
YMGI Smart Technologies
·
Auto-Restart
: After a power cut the unit will restart automatically with the previous function setting when the power returns.
·
Intelligent Auto-Defrosting:
The unit can enter or quit the defrosting mode automatically by timely detecting the frosting situation of the outdoor unit.
·
Sleep Mode:
Because our body temperature cools down as we sleep, the unit automatically adjusts the setting for all-night comfort.
·
Air Purifying and Deodorizing Filters:
Industrial development has offered from one side a better life style, but on the other side, it has increased polluting substances presence in the air that helps in spreading of various kinds of diseases. Among the polluting agents, the ones we can more frequently find at home are anti-bacterial dust particles, moulds and etc, which are causing allergic phenomenon, breathing and typical upper respiratory problems. This dual washable filter screen is effective in preventing anti-bacteria mould and duct particles and ensuring a healthy indoor environment.
·
Turbo Mode:
This function enables the unit to reach the preset temperature in the shortest time.
·
Self-diagnosis and Auto-Protection Function:
This function can electronically detect the errors and display the diagnosis by a series of flashing LEDs on the indoor unit. Then the unit will automatically switch to protection mode.
IMPORTANT NOTES ABOUT THE DC INVERTER SYSTEM VARIOUS PERFORMANCES
·
The rated performance data printed on the nameplate were tested per AHRI 210/240 standards at standard indoor & outdoor conditions and standard installation set-up.
·
Actually the DC inverter outdoor unit could modulate to match whatever capacity needs are called/requested from indoor side, to produce a wide range of capacities, minimum could be about 15% of the rated number and maximum could be around 160% of the rated number.
·
Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period: soft starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes.
·
Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting pipe length/ bending, elevation difference between indoor and outdoor units, refrigerant charging level, vacuum level, leakage, air or moisture or contamination level, foreign substance left in the piping, indoor filter clean level, indoor and outdoor coil conditions, and other factors.
·
When the rated total capacity of all the indoor units exceeds the rated capacity of outdoor unit, each indoor unit may not output the rated capacity and one may differ from other, upon other installation/operation factors, it all units are turned on to run compressor simultaneously.
PIPE ADAPTER
·
Whenever the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas pipe of 1/2" or 5/8", one 3/8" - 1/2" or 3/8" - 5/8" adapter is to be used in between. This reducer is packed separately and shall be installed at job site.
·
Any indoor unit is 30' or more apart from the outdoor unit, better to adjust refrigerant. If it is 50' or more apart, better to upper size the copper lines and adjust refrigerant.
·
Any run cannot be more than 100' apart from the outdoor unit; otherwise, that indoor unit capacity may be reduced
BTU / Area Coverage Guide
24000 BTU covers Approx 1100
ft²
* Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those affect insulation.
Application
Green House
Hotel
Home
Office
Common Hall
Condos
Resort
Factory
Nursing Home
Residential Apartment
Office
Restaurant
Bar and Pub
Package Include
Condenser R410A pre-charged (outdoor unit)
2 X Air Handler w/wall bracket (
for
indoor unit)
2 X Wireless Remote control
2 X Installation kit at 25Ft for each indoor unit (Insulated copper line set with nuts, control cable and misc.)
Installation and Operation Manuals
Manufacturer warranty Certificate
Warranty
All YMGI products come with standard 7 years limited warranty for compressor and 2 year limited warranty of parts for indoor units and installation kit. If you have any questions related to the operation of your equipment you are always welcome to contact us by email or phone and we will there to assist. Our contact information will be available in the warranty certificate.
Notice and Installation
YMGI does not provide installation for equipment. Customer will need to hire a licensed HVAC technician and install the equipment in a professional manner.
Installation by unlicensed personnel will automatically void YMGI standard warranty and it is strongly not recommended as it may cause danger to your property. YMGI and bizlander cannot be held liable for any damage that caused by improper installation. Please be advised that federal law prohibits opening any refrigeration line by anyone not properly licensed.
Please be noted returned warranty certificate will be deemed as valid only if it is signed, dated and noted with details of technician which responsible for the installation.
Disclaimer
YMGI endeavour to ensure all information given here (include technical data, and other information) is correct. However due to omissions, errors and out-of-date data from constant improvement, YMGI and bizlander reserve all rights to modify any part of the content without notice. Every reasonable effort has been made to ensure all information contained here is correct.
More Items!
View more great items
YMGI 9000 BTU Packaged Terminal Air Conditioner 265-277V Heat Pump 3KW HEATER
$695.00
YMGI 15000BTU Packaged Terminal air Conditioner 265-277V WITH 3KW HEATER
$719.00
YMGI 12000BTU Packaged Terminal Air conditioner 265-277V 3KW HEATER
$755.00
YMGI 9000 BTU PTAC PACKAGED TERMINAL 265/277 V AIR CONDITIONER WITH 3KW HEATER
$659.00
Listed by
Frooition
Frooition | No-js Template | eBay design, eBay store design, eBay shop design, eBay template design, eBay listing design, eBay Listing Tool (ver:froo_no_js)